KQ2800KDT超聲波清洗器是采用先進、成熟的電路設計制造的;元器件采用優質的器件,并經過嚴格的質量檢驗;再經過先進的加工工藝制造而成的新一代功率超聲清洗設備,工作可靠,效率高,輸出功率穩定。下面是該系列超聲波清洗器使用方法和注意事項中英文對照版,KQ2800KDT
超聲波清洗器必須嚴格按以下說明操作:
1、供電電源線應接AC.220V電源,其中紅線為火線,綠線為零線,黑線為接地,與地線相連。電源電壓應保持在220v±10%的范圍內,電壓過低將導致繼電器不能可靠吸合,電壓過高將導致超聲波發生器損壞,(注意:供電電源必須有漏電保護開關。。Voltage for 220V, Power Voltage will be in between 220V+10% and 220V-10%, low voltage will cause relay couldn’t liable connection, high voltage will cause the demage of ultrasonic generator.
2、超聲波清洗槽最佳清洗溫度在40℃左右,嚴禁清洗槽內無水開機,否則會因空載而損壞機器,切忌!ultrasonic cleaning tank’s temperature for 40degree, prohibiting no-water operation in cleaning tank, or else it will demage mchine, attention!
3、超聲波發生器里面的風機是供整機散熱的,應保證其正常運轉和散熱通道的暢通。the fun of ultrasonic generator is to provide heat elimination , so we should keep nomal operation and good intake of heat elimination
4、超聲波清洗機應置于干燥、無腐蝕性的環境中,溫度應低于30攝氏度。to put ultrasonic cleaner in dry place, non-corrosion’s environment, the temp is not exceeds 30 degree.
5、本機作用說明:A、超聲波功能使用:將超聲開關(ULTRASONIC)推至ON位置,稍等片刻,超聲波工作,進行工件清洗(超聲波工作時間受定時器控制)。B、定時器使用:
定時范圍:0S——99.99H拔碼開關中間的顯示數字為設定的時間。其中,中間的加減調整為:H、M、S H代表小時;M代表分鐘; S代表秒;其它拔碼調整為0——9 例如:12 S 22 為12.22秒 30M55 為30.55分 99H99 為99.99小時 C、加熱及溫控使用說明將加熱開關(HEATING)推至ON位置,幾秒鐘后,溫控儀將顯示測量溫度與控制溫度。上面顯示的是測量溫度,下面顯示的是控制溫度,當測量溫度低于控制溫度時,溫控儀上OUT燈亮,處于加熱狀態;當測量溫度高于控制溫度時,溫控儀上OUT燈滅,停止加熱?刂茰囟仍O置方法:按SET鍵—進入SP菜單---按向上或向下箭頭調整溫度,調完后按SET鍵退出即可。
6、嚴禁帶電拆機或檢修!to draw out power when we dismantal machine.